05 0303_05 0302_2182021_004100.mp4
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
16.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
32.6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
152.8 ft. - General Observation - SPORATIC POSSIBLE OLD COATING ON PIPE
315.4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 315.4 | SAM | SEVERE AGG |
| 0 | AMH | 12:35AM |
| 0 | MWL | — |
| 2 | SAM | SEVERE AGG |
| 0 | MWM | — |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 32.6 | SAM | SEVERE AGG |
| 328.6 | SSS | BLISTERING PEELING CONCRETE |
| 16.1 | SSS | PEELING CONCRETE |
| 152.8 | MGO | SPORATIC POSSIBLE OLD COATING ON PIPE |
| 328.6 | SAM | SEVERE AGG |
| 328.9 | AMH | 1:00AM |