Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2021, 10:23 AM
  • 05 1994_05 1993_01292021_025032.mp4

Date
01/29/2021
W/O
870570
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00538
PipeID
P07186
Time
2:23 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8512
Sewer Name
05 WESTERN AVENUE TRUNK
City
RANCHO PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_870570_TV05115_JAN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
21 in.
Upstream MH
05 1994
Downstream MH
05 1993
Dir. of Survey
Downstream
Length Surveyed
330.2 ft.
Total Length
330.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
130
Pipe schematic from manhole 05 1994 to 05 1993
MH: 05 1994MH: 05 1993downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 19942 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - PIPE IS LINED30 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN232.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN328 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish330 ft. MGO - General Observation - ROACHES @ MH330.2 ft. AMH - Downstream Manhole, Survey Ends - 5 1993

Observations (10)

DistanceCodeObservation
30TFOPEN
2DAGS
0MWL
328DAGS
330MGOROACHES @ MH
232.7TFOPEN
0MWM
2MGOPIPE IS LINED
0AMH05 1994
330.2AMH5 1993

Properties (8)

additional_info
630138012821201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-01-29T02:23:01-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP