Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2021, 08:33 AM
  • 08 0031_08 0030_02032021_005408.mp4

Date
02/03/2021
W/O
870237
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00016
PipeID
P00033
Time
12:33 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7833
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_870237_TV08115_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0031
Downstream MH
08 0030
Dir. of Survey
Downstream
Length Surveyed
58.5 ft.
Total Length
58.5 ft.
Structural Index
3
Structural Quick
513A
Structural Rating
62
O&M Index
2
O&M Quick
2900
O&M Rating
18
Overall Index
2
Overall Quick
Overall Rating
80
Pipe schematic from manhole 08 0031 to 08 0030
MH: 08 0031MH: 08 0030downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00310 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start10.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"10.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES10.2 ft. BSV - Broken Soil Visible, from 12 to 12 o'clock, within 8 inches of joint: YES54.1 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start54.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"56 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish56 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish58.5 ft. MSA - Survey Abandoned - DEBRIS58.5 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish58.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    10.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Broken Soil Visible, from 12 to 12 o'clock, within 8 inches of joint: YES

    10.2 ft. - Broken Soil Visible, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Deposits Settled Compacted,  10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    54.1 ft. - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
56CM
54.1DSC
58.5MSADEBRIS
58.5DSC
0MWM
58.5DAGS
2SSS
2CM
10.2TFC
0AMH08 0031
10.2CL
0MWL
56SSS
2DAGS
10.2BSV
54.1TFC

Properties (7)

additional_info
630138020221201
custom_field_three
BROKEN PIPE
custom_field_two
5
customer
1
datetime
2021-02-03T00:33:13-08:00
documentation
PROPIPE
is_lateral_inspection
false