- Date
- 02/02/2021
- W/O
- 870133
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00215
- PipeID
- P00803
- Time
- 12:46 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7850
- Sewer Name
- 01 NADEAU TRUNK, SECTS 2&1
- City
- FLORENCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- RFIR_WO_870133_TV01126_JAN2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 27 in.
- Upstream MH
- 01 0332
- Downstream MH
- 01 0333
- Dir. of Survey
- Upstream
- Length Surveyed
- 414.3 ft.
- Total Length
- 414.3 ft.
- Structural Index
- 3
- Structural Quick
- 3O2O
- Structural Rating
- 410
- O&M Index
- 2
- O&M Quick
- 2O00
- O&M Rating
- 164
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 574
Pipe schematic from manhole 01 0332 to 01 0333 Observation photos (4)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - 65% MAG COAT