- Date
- 09/02/2015
- W/O
- 0521101
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00226
- PipeID
- P02110
- Time
- 1:37 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6502
- Sewer Name
- 01 WILCOX AVENUE TRUNK, EXTENSION #1
- City
- SOUTH GATE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Capital Improvement Program Assesment
- Project
- 20150902MDM_WILC0X_AVENUE_TRUNK_EXTENSION_1
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 01 1199A
- Downstream MH
- 01 1199
- Dir. of Survey
- Downstream
- Length Surveyed
- 100.4 ft.
- Total Length
- 100.4 ft.
- Structural Index
- 3
- Structural Quick
- 3B25
- Structural Rating
- 49
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 53
Pipe schematic from manhole 01 1199A to 01 1199 Observation photos (5)

2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

26.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

54.6 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES

55.6 ft. - General Photograph

81.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT