Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2015, 09:29 AM
Date
06/11/2015
W/O
0502638
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00228
PipeID
P01789
Time
2:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6348
Sewer Name
01 WRIGHT ROAD TRUNK
City
`SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Capital Improvement Program Assesment
Project
20150611MDM_WRIGHT_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
01 0952
Downstream MH
01 0951
Dir. of Survey
Downstream
Length Surveyed
298.4 ft.
Total Length
298.4 ft.
Structural Index
3
Structural Quick
443H
Structural Rating
196
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
200
Pipe schematic from manhole 01 0952 to 01 0951
MH: 01 0952MH: 01 0951downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:45AM0 ft. MGO - General Observation - MH CONN STUB 3:000 ft. MGO - General Observation - MH CONN STUB 9:000 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area4.2 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT8.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SLIGHT11.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE14.7 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT16.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE19.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish20.3 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SLIGHT25.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT28.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT30.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE38.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT60.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish66.5 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - HAIRLINE79.4 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE86.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish104.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT107 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE111.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish114.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE119.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT135 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT142.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE161.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish161.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT165.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT168 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT177.6 ft. MGP - General Photograph - LONG SLIGHT 12:00181.2 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT191.3 ft. MWL - Water Level, 30 %of cross sectional area191.3 ft. MWM - Water Mark, 60 %of cross sectional area193.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT196.3 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT198.4 ft. B - Broken, at 12 o'clock, within 8 inches of joint: YES - MODERATE198.4 ft. B - Broken, at 12 o'clock, within 8 inches of joint: YES, Start - MODERATE202.9 ft. B - Broken, at 12 o'clock, within 8 inches of joint: YES211.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT217.5 ft. B - Broken, at 12 o'clock, within 8 inches of joint: YES, Finish - MODERATE217.5 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - MODERATE217.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish221.7 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT226.8 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT240.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT240.5 ft. FS - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish257.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT274.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE280.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish292.1 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT292.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES298.4 ft. AMH - Downstream Manhole, Survey Ends - 4:45AM

Observation photos (15)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES,  - SLIGHT

    8.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SLIGHT

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    38.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    66.5 ft. - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE

    79.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    104.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    135 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    142.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    161.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • General Photograph - LONG SLIGHT 12:00

    177.6 ft. - General Photograph - LONG SLIGHT 12:00

  • Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT

    181.2 ft. - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

    193.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

  • Broken, at 12 o'clock, within 8 inches of joint: YES - MODERATE

    198.4 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES - MODERATE

  • Broken, at 12 o'clock, within 8 inches of joint: YES, Start - MODERATE

    198.4 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES, Start - MODERATE

  • Broken, at 12 o'clock, within 8 inches of joint: YES

    202.9 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES

  • Broken, at 12 o'clock, within 8 inches of joint: YES, Finish - MODERATE

    217.5 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES, Finish - MODERATE

Observations (54)

DistanceCodeObservation
193.8FMSLIGHT
217.5BMODERATE
20.3FCSLIGHT
119.5FCSLIGHT
161.1FL
217.5FSMODERATE
79.4FMHAIRLINE
14.7FCSLIGHT
111.2FL
19.3FL
30.5FLHAIRLINE
0AMH3:45AM
8.6FLSLIGHT
107FCHAIRLINE
211.6FCSLIGHT
16.2FLHAIRLINE
198.4BMODERATE
202.9B
0MGOMH CONN STUB 3:00
86.6FC
38.6FLSLIGHT
298.4AMH4:45AM
191.3MWL
165.6FCSLIGHT
292.6CL
226.8FCSLIGHT
161.1FLSLIGHT
196.3FCSLIGHT
60.7FL
191.3MWM
142.6FLHAIRLINE
11.9FCHAIRLINE
177.6MGPLONG SLIGHT 12:00
240.5FLSLIGHT
0MGOMH CONN STUB 9:00
181.2FCSLIGHT
28.4FLSLIGHT
66.5FCHAIRLINE
292.1FCSLIGHT
240.5FS
0MWL
198.4BMODERATE
114.8FMHAIRLINE
4.2FCSLIGHT
135FMSLIGHT
274.6FCHAIRLINE
217.5FL
104.2FLSLIGHT
257.3FLSLIGHT
280.5FL
221.7FCSLIGHT
168FCSLIGHT
25.9FCSLIGHT
0MWM

Properties (6)

custom_field_three
MODERATE BROKEN PIPE JOINT TO JOINT LONGER
custom_field_two
1
customer
LACSD
datetime
2015-06-11T02:29:32-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false