Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 14, 2015, 08:57 AM
  • C 0593_C 0592_14052015_021240.mp4

Date
05/14/2015
W/O
496959
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00929
PipeID
P22829
Time
1:57 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2379
Sewer Name
C JOINT OUTFALL C - UNIT 3E REPLACEMENT
City
LONGBEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
19
Purpose
Routine Assessment
Project
WO_496959_TV03066_2015APRIL
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Upstream MH
C 0593
Downstream MH
C 0592
Dir. of Survey
Downstream
Length Surveyed
379.8 ft.
Total Length
379.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole C 0593 to C 0592
MH: C 0593MH: C 0592downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - INFILTRATION AT MH0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 05933.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start374.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish379.8 ft. AMH - Downstream Manhole, Survey Ends - C 0592379.8 ft. MGO - General Observation - INFILTRATION AT MH

Observation photos (2)

  • General Observation - INFILTRATION AT MH

    0 ft. - General Observation - INFILTRATION AT MH

  • General Observation - INFILTRATION AT MH

    379.8 ft. - General Observation - INFILTRATION AT MH

Observations (8)

DistanceCodeObservation
379.8AMHC 0592
0MWM
0MGOINFILTRATION AT MH
0MWL
0AMHC 0593
374.9DAGS
379.8MGOINFILTRATION AT MH
3.8DAGS

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2015-05-14T01:57:17-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
20001223