Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 19, 2021, 10:23 PM
  • H 0936_H 0935_01192021_143812.mp4

Date
01/19/2021
W/O
865007
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P15349
Time
2:23 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8501
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_865007_TV21022_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
H 0936
Downstream MH
H 0935
Dir. of Survey
Downstream
Length Surveyed
451.7 ft.
Total Length
451.7 ft.
Structural Index
3
Structural Quick
3Q2Q
Structural Rating
445
O&M Index
2
O&M Quick
2Q00
O&M Rating
178
Overall Index
2
Overall Quick
Overall Rating
623
Pipe schematic from manhole H 0936 to H 0935
MH: H 0936MH: H 0935downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 09362 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 75% MAG COAT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start284.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"291.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN449 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish449 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish449 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish451 ft. MGO - General Observation - ROACHES @ MH451.7 ft. AMH - Downstream Manhole, Survey Ends - H 0935

Observations (15)

DistanceCodeObservation
0MGOCONN @ MH 3 O'CLOCK/OPEN
451MGOROACHES @ MH
0MWM
2SAV
0MWL
2SSS
449SAV
449DAGS
2MGO75% MAG COAT
291.1TFOPEN
284.7TFC
0AMHH 0936
2DAGS
451.7AMHH 0935
449SSS

Properties (7)

additional_info
630138011921072
custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2021-01-19T14:23:49-08:00
documentation
PRO PIPE
is_lateral_inspection
false