- Date
- 01/13/2021
- W/O
- 865007
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z01005
- PipeID
- P15342
- Time
- 1:58 AM
- Certificate
- U-115-06002794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8376
- Sewer Name
- H JOINT OUTFALL H - UNIT 7C
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- WO_865007_TV21022_DEC2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 36 in.
- Upstream MH
- H 0929
- Downstream MH
- H 0928
- Dir. of Survey
- Downstream
- Length Surveyed
- 447.4 ft.
- Total Length
- 447.4 ft.
- Structural Index
- 3
- Structural Quick
- 3b2b
- Structural Rating
- 865
- O&M Index
- 2
- O&M Quick
- 2Q00
- O&M Rating
- 178
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1043
Pipe schematic from manhole H 0929 to H 0928 Observation photos (4)

2 ft. - General Observation - 65% MAG COAT

20.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

20.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

398.6 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4", 12" - OPEN