Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2021, 07:35 AM
  • 05 1598_05 1597_01262021_002147.mp4

Date
01/25/2021
W/O
870098
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00485
PipeID
P06822
Time
11:35 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8507
Sewer Name
05 MARICOPA STREET TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_870098_TV05070_JAN2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
15 in.
Upstream MH
05 1598
Downstream MH
05 1597
Dir. of Survey
Downstream
Length Surveyed
336.2 ft.
Total Length
336.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1598 to 05 1597
MH: 05 1598MH: 05 1597downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 15981.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"30.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"74.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"78 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"133.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"137.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"188.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"192.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"244.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"248.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"295.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - ROOTS299.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"333.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK336.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1597

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    1.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - ROOTS

    295.6 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - ROOTS

Observations (20)

DistanceCodeObservation
248.2TFC
0MGOCONNECTION AT MH 9 O'CLOCK
244.5TFA
0MWM
0MWL
0AMH05 1598
26.4TFA
74.1TFC
188.8TFC
30.6TFC
295.6TFAROOTS
133.5TFC
299.5TFC
137.3TFC
333.1SAV
336.2MGOCONNECTION AT MH 9 O'CLOCK
78TFC
1.9SAV
192.9TFC
336.2AMH05 1597

Properties (7)

additional_info
630138012521201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-01-25T23:35:42-08:00
documentation
PRO PIPE
is_lateral_inspection
false