Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2021, 11:06 AM
  • 02 0553_A 1223_01272021_032513.mp4

Date
01/27/2021
W/O
864827
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00244
PipeID
P02872
Time
3:06 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8438
Sewer Name
02 DISTRICT #2 MAIN TRUNK
City
COMMERCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
WO_864827_TV02091_DEC2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
36 in.
Width
42 in.
Upstream MH
02 0553
Downstream MH
A 1223
Dir. of Survey
Downstream
Length Surveyed
414.6 ft.
Total Length
414.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
413F
O&M Rating
363
Overall Index
2
Overall Quick
Overall Rating
363
Pipe schematic from manhole 02 0553 to A 1223
MH: 02 0553MH: A 1223downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 05530 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. MGO - General Observation - MAG COATING THROUGHOUT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start18.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS99.4 ft. MGO - General Observation - ABANDONED MH.227.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - DEBRIS227.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish249.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"253.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"412.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish414.6 ft. MGO - General Observation - STOP LOG CONNECTION AT MH 12 O'CLOCK414.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE414.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK414.6 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish414.6 ft. AMH - Downstream Manhole, Survey Ends - A 1223

Observation photos (4)

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - ABANDONED MH.

    99.4 ft. - General Observation - ABANDONED MH.

  • General Observation - COCKROACHES IN MANHOLE

    414.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
414.6MGOSTOP LOG CONNECTION AT MH 12 O'CLOCK
414.6MGOCOCKROACHES IN MANHOLE
414.6MGOCONNECTION AT MH 3 O'CLOCK
0AMH02 0553
227.9DSZDEBRIS
18.2DSZDEBRIS
2MGOMAG COATING THROUGHOUT
414.6DSZ
249.6TF
99.4MGOABANDONED MH.
227.9DSZ
2DAGS
253.8TFA
0MWL
414.6AMHA 1223
0MWM
412.3DAGS

Properties (7)

additional_info
SC411903
custom_field_three
MAG COATING/DEBRIS
custom_field_two
5
customer
1
datetime
2021-01-27T03:06:48-08:00
documentation
PRO PIPE
is_lateral_inspection
false