Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2021, 11:26 AM
  • 02 0576_02 0575_01222021_042138.mp4

Date
01/22/2021
W/O
864827
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00244
PipeID
P02895
Time
3:26 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8429
Sewer Name
02 DISTRICT #2 MAIN TRUNK
City
COMMERCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
WO_864827_TV02091_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
42 in.
Upstream MH
02 0575
Downstream MH
02 0576
Dir. of Survey
Upstream
Length Surveyed
401.6 ft.
Total Length
401.6 ft.
Structural Index
3
Structural Quick
3I21
Structural Rating
146
O&M Index
2
O&M Quick
413N
O&M Rating
394
Overall Index
3
Overall Quick
Overall Rating
540
Pipe schematic from manhole 02 0575 to 02 0576
MH: 02 0575MH: 02 0576upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 05760.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish0.1 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE59.6 ft. OBR - Obstacles Rocks, 10 %of cross sectional area, from 05 to 07 o'clock98.9 ft. MGO - General Observation - ABANDONED MH103.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start103.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish125.4 ft. SZ - Surface Other, from 09 to 02 o'clock, within 8 inches of joint: YES - MISSING TILE149.7 ft. SZ - Surface Other, at 02 o'clock, within 8 inches of joint: YES - MISSING TILE170.1 ft. SZ - Surface Other, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING TILES170.1 ft. SZ - Surface Other, at 10 o'clock, within 8 inches of joint: YES - MISSING TILE237.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start291.1 ft. SZ - Surface Other, from 10 to 11 o'clock, within 8 inches of joint: YES - MISSING TILE381.1 ft. DSF - Deposits Settled Fine, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start395.8 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES399.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start401.6 ft. AMH - Downstream Manhole, Survey Begins - 02 0575401.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE401.6 ft. MWM - Water Mark, 50 %of cross sectional area401.6 ft. MWL - Water Level, 30 %of cross sectional area401.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (14)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    5.8 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Deposits Settled Fine,  15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    20.5 ft. - Deposits Settled Fine, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Other, from 10 to 11 o'clock, within 8 inches of joint: YES - MISSING TILE

    110.5 ft. - Surface Other, from 10 to 11 o'clock, within 8 inches of joint: YES - MISSING TILE

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    164.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING TILES

    231.5 ft. - Surface Other, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING TILES

  • Surface Other, at 10 o'clock, within 8 inches of joint: YES - MISSING TILE

    231.5 ft. - Surface Other, at 10 o'clock, within 8 inches of joint: YES - MISSING TILE

  • Surface Other, at 02 o'clock, within 8 inches of joint: YES - MISSING TILE

    251.9 ft. - Surface Other, at 02 o'clock, within 8 inches of joint: YES - MISSING TILE

  • Surface Other, from 09 to 02 o'clock, within 8 inches of joint: YES - MISSING TILE

    276.2 ft. - Surface Other, from 09 to 02 o'clock, within 8 inches of joint: YES - MISSING TILE

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    297.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ABANDONED MH

    302.7 ft. - General Observation - ABANDONED MH

  • Obstacles Rocks, 10 %of cross sectional area, from 05 to 07 o'clock

    342 ft. - Obstacles Rocks, 10 %of cross sectional area, from 05 to 07 o'clock

  • General Observation - COCKROACHES IN MANHOLE

    401.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (23)

DistanceCodeObservation
297.9SAP
2DAGS
401.5DAGS
251.9SZMISSING TILE
0AMH02 0575
0MGOCOCKROACHES IN MANHOLE
164.5CM
276.2SZMISSING TILE
0MWM
0MWL
297.9CM
401.5DSF
110.5SZMISSING TILE
342OBR
0MGOCONNECTION AT MH 9 O'CLOCK
401.5SAP
302.7MGOABANDONED MH
401.6AMH02 0576
5.8CL
231.5SZMISSING TILES
231.5SZMISSING TILE
401.5MGOCOCKROACHES IN MANHOLE
20.5DSF

Properties (7)

additional_info
630069012121204
custom_field_three
PROJECTING AGGREGATE/CRACKS
custom_field_two
2
customer
1
datetime
2021-01-22T03:26:23-08:00
documentation
PRO PIPE
is_lateral_inspection
false