Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2017, 10:21 AM
  • 17 0012_17 0011 _02062017_022257.mp4

Date
02/06/2017
W/O
618954
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13737
Time
2:21 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4232
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
07
Purpose
Routine Assessment
Project
WO_618954_TV17003_FEB2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
17 0012
Downstream MH
17 0011
Dir. of Survey
Downstream
Length Surveyed
457.8 ft.
Total Length
457.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2R00
O&M Rating
190
Overall Index
2
Overall Quick
Overall Rating
193
Pipe schematic from manhole 17 0012 to 17 0011
MH: 17 0012MH: 17 0011downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 17 00122 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start39.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"50.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"99.9 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"144.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"173 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"185.3 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"189.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"238.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"254.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"278.7 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"320 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"323.5 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"368.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"388.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"390.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO408.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"449.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"457.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK457.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish457.8 ft. AMH - Downstream Manhole, Survey Ends - 17 0011

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO

    390.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO

Observations (25)

DistanceCodeObservation
185.3TBC
254.4TBA
408.5TBA
388.6TBA
368.1TBA
50.7TB
457.8MGOACTIVE CONNECTION AT MH 9 O'CLOCK
457.8DAGS
0MWL
238.1TBA
0MWM
119.9TBA
320TBA
278.7TBC
449.2TBA
39.2TBA
99.9TBC
0AMH17 0012
2DAGS
323.5TBC
173TBA
144.8TB
189.2TBA
457.8AMH17 0011
390.5CM

Properties (6)

additional_info
SC306734
custom_field_two
4
customer
LACSD
datetime
2017-02-06T02:21:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false