Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 20, 2016, 07:10 AM
  • E 0060_E 0059_20161020_012455.mp4

Date
10/20/2016
W/O
597393
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00028
PipeID
P11290
Time
12:10 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3858
Sewer Name
E JOINT OUTFALL E - UNIT 2
City
LYNWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
V
Project
WO_597393_TV01124_OCT2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Upstream MH
E 0059
Downstream MH
E 0060
Dir. of Survey
Upstream
Length Surveyed
15.2 ft.
Total Length
15.2 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole E 0059 to E 0060
MH: E 0059MH: E 0060upstream0 ft. OBN - Obstacles Construction Debris, 25 %of cross sectional area, from 04 to 08 o'clock - NOT VISIBLE0 ft. MSA - Survey Abandoned - SEVERE DEBRIS 25%0 ft. MGO - General Observation - Magnesium hydroxide coating finish0 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish9.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.2 ft. MGO - General Observation - Magnesium hydroxide coating start15.2 ft. MWM - Water Mark, 25 %of cross sectional area15.2 ft. MGO - Reversal Inspection15.2 ft. AMH - Downstream Manhole, Survey Begins - E 005915.2 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
6SAP
6MGOMagnesium hydroxide coating start
0MGO
15.2OBNNOT VISIBLE
15.2MSASEVERE DEBRIS 25%
15.2MGOMagnesium hydroxide coating finish
0AMHE 0059
15.2SAP
0MWL

Properties (6)

additional_info
SC301937
custom_field_two
3
customer
LACSD
datetime
2016-10-20T00:10:19-07:00
documentation
PRO PIPE
is_lateral_inspection
false