Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2016, 06:48 AM
  • 18 0420_18 0419_20160318_000202.mp4

Date
03/17/2016
W/O
557858
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00699
PipeID
P14255
Time
11:48 PM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3228
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_557858_TV18044_2016MAR
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
18 0420
Downstream MH
18 0419
Dir. of Survey
Downstream
Length Surveyed
320.8 ft.
Total Length
320.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 18 0420 to 18 0419
MH: 18 0420MH: 18 0419downstream0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 04200 ft. MWL - Water Level, 45 %of cross sectional area2 ft. MGO - General Observation - MAGNEZIUM H.O. START 45%3.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start318 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish320.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0419

Observation photos (2)

  • Water Mark, 60 %of cross sectional area

    0 ft. - Water Mark, 60 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
3.3DAGS
0MWM
320.8AMH18 0419
0AMH18 0420
0MWL
318DAGS
2MGOMAGNEZIUM H.O. START 45%

Properties (6)

additional_info
SC305319
custom_field_two
4
customer
LACSD
datetime
2016-03-17T23:48:17-07:00
documentation
PRO-PIPE
is_lateral_inspection
false