Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2016, 09:15 AM
  • G 0118_G 0117_20160126_022249_.mp4

Date
01/26/2016
W/O
547569
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01180
PipeID
P01445
Time
1:15 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3126
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_547569_TV01236_JAN2016
Sewer Type
GRAVITY
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0118
Downstream MH
G 0117
Dir. of Survey
Downstream
Length Surveyed
10.1 ft.
Total Length
10.1 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole G 0118 to G 0117
MH: G 0118MH: G 0117downstream0 ft. AMH - Upstream Manhole, Survey Begins - G 01180 ft. MWL - Water Level, 90 %of cross sectional area0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MGO - General Observation - BULKHEAD AT MANHOLE7 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES10.1 ft. MSA - Survey Abandoned - DUE TO HIGH FLOW CAMERA HITTING TOP OF PIPE AT LOW FLOW CONDITIONS10.1 ft. MGO - General Observation - CAMERA HITTING TOP OF PIPE

Observation photos (2)

  • Survey Abandoned - DUE TO HIGH FLOW CAMERA HITTING TOP OF PIPE AT LOW FLOW CONDITIONS

    10.1 ft. - Survey Abandoned - DUE TO HIGH FLOW CAMERA HITTING TOP OF PIPE AT LOW FLOW CONDITIONS

  • General Observation - CAMERA HITTING TOP OF PIPE

    10.1 ft. - General Observation - CAMERA HITTING TOP OF PIPE

Observations (7)

DistanceCodeObservation
0AMHG 0118
0MWL
10.1MSADUE TO HIGH FLOW CAMERA HITTING TOP OF PIPE AT LOW FLOW CONDITIONS
7SAM
0MWM
0MGOBULKHEAD AT MANHOLE
10.1MGOCAMERA HITTING TOP OF PIPE

Properties (6)

additional_info
SC225513
custom_field_two
5
customer
LACSD
datetime
2016-01-26T01:15:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false