Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2016, 10:59 AM
  • G 0143_G 0142_20160126_041309_.mp4

Date
01/26/2016
W/O
547569
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01180
PipeID
P01466
Time
2:59 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3126
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_547569_TV01236_JAN2016
Sewer Type
GRAVITY
Material
RCP-CTL
Shape
Circular
Height
36 in.
Upstream MH
G 0143
Downstream MH
G 0142
Dir. of Survey
Downstream
Length Surveyed
83.5 ft.
Total Length
83.5 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole G 0143 to G 0142
MH: G 0143MH: G 0142downstream0 ft. AMH - Upstream Manhole, Survey Begins - G 01430 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MWL - Water Level, 75 %of cross sectional area12.6 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - MISSING TILES83.5 ft. MSA - Survey Abandoned - FLOW NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT HITTING TOP OF PIPE83.5 ft. MGO - General Observation - FLOW IS NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT IS HITTING TOP OF PIPE

Observation photos (1)

  • Survey Abandoned - FLOW NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT HITTING TOP OF PIPE

    83.5 ft. - Survey Abandoned - FLOW NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT HITTING TOP OF PIPE

Observations (6)

DistanceCodeObservation
83.5MSAFLOW NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT HITTING TOP OF PIPE
12.6SAMMISSING TILES
0AMHG 0143
0MWM
83.5MGOFLOW IS NOT STRONG ENOUGH TO PULL BOAT THROUGH PIPE, BOAT IS HITTING TOP OF PIPE
0MWL

Properties (6)

additional_info
SC225513
custom_field_two
5
customer
LACSD
datetime
2016-01-26T02:59:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false