Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2016, 08:37 AM
  • 02 1548_02 1547_20160113_005645_.mp4

Date
01/13/2016
W/O
544149
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00230
PipeID
P03980
Time
12:37 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2954
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_544149_TV02006_JAN2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 1548
Downstream MH
02 1547
Dir. of Survey
Downstream
Length Surveyed
297.2 ft.
Total Length
297.2 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
174
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
176
Pipe schematic from manhole 02 1548 to 02 1547
MH: 02 1548MH: 02 1547downstream0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15480 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. MWL - Water Level, 5 %of cross sectional area7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start36.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"47 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"70.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"72.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"101.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"118.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"121.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"147.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"169.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"172.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"197.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"218.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"220.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"246.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"264 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"266.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"297.2 ft. VC - Vermin Cockroach297.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish297.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1547297.2 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
7CM
0VC
297.2VC
197.6TFC
121.8TF
147.4TF
101.1TF
266.8TFC
0MWM
297.2CM
47TF
72.6TF
36.5TFC
297.2AMH02 1547
169.8TFC
297.2MGOLATERAL AT MH 9 OCLOCK
172.7TF
0AMH02 1548
220.7TF
218.4TF
70.4TFA
0MGOLATERAL AT MH 9 OCLOCK
246.6TF
118.9TFC
0MWL
264TFC

Properties (6)

additional_info
SC224965
custom_field_two
3
customer
LACSD
datetime
2016-01-13T00:37:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false