Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2016, 08:21 AM
  • 02 1549_02 1548_20160113_003709_.mp4

Date
01/13/2016
W/O
544149
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00230
PipeID
P03981
Time
12:21 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2954
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_544149_TV02006_JAN2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 1549
Downstream MH
02 1548
Dir. of Survey
Downstream
Length Surveyed
313.1 ft.
Total Length
313.1 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
177
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
179
Pipe schematic from manhole 02 1549 to 02 1548
MH: 02 1549MH: 02 1548downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 15490 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. VC - Vermin Cockroach13.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"54.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"77.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"80.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"103.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"124 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"126.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"152.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4"178.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"180.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"204.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"227.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"229.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"258.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"281 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"284.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"310 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish312.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK313.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1548313.1 ft. VC - Vermin Cockroach

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
284.1TF
313.1AMH02 1548
312.1MGOLATERAL AT MH 9 OCLOCK
178.5TFC
180.7TFC
124TFC
152.5TF
310CM
0AMH02 1549
103.6TF
313.1VC
41.1TFC
227.2TF
80.2TFC
0MGOLATERAL AT MH 9 OCLOCK
281TFC
54.1TF
204.1TF
77.5TF
126.5TFC
13.8CM
0VC
229.9TFC
258.2TF

Properties (6)

additional_info
SC224965
custom_field_two
3
customer
LACSD
datetime
2016-01-13T00:21:33-08:00
documentation
PRO PIPE
is_lateral_inspection
false