Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2017, 04:04 PM
  • A 0308_A 0307_5242017_091408.mp4

Date
05/24/2017
W/O
0640849
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z00325
PipeID
P08218
Time
9:04 AM
Certificate
PENDING
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7414
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
20170524MI_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
A 0308
Downstream MH
A 0307
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole A 0308 to A 0307
MH: A 0308MH: A 0307downstream0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 09:30 AM2 ft. LD - Alignment Down, 45 %2 ft. MGO - General Observation - MAG COAT, 8 TO 4 OCLOCK, 25% INTACT2 ft. MGO - General Observation - GASKET MATERIAL AT THE JOINTS VISIBLE2 ft. ISSRH - Intruding Sealing Ring Hanging, 5 %of cross sectional area, from 08 to 04 o'clock2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MSA - Survey Abandoned - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON2.1 ft. MGO - General Observation - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

Observation photos (5)

  • Alignment Down, 45 %

    2 ft. - Alignment Down, 45 %

  • General Observation - MAG COAT, 8 TO 4 OCLOCK, 25% INTACT

    2 ft. - General Observation - MAG COAT, 8 TO 4 OCLOCK, 25% INTACT

  • General Observation - GASKET MATERIAL AT THE JOINTS VISIBLE

    2 ft. - General Observation - GASKET MATERIAL AT THE JOINTS VISIBLE

  • Intruding Sealing Ring Hanging, 5 %of cross sectional area, from 08 to 04 o'clock

    2 ft. - Intruding Sealing Ring Hanging, 5 %of cross sectional area, from 08 to 04 o'clock

  • General Observation - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

    2.1 ft. - General Observation - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

Observations (9)

DistanceCodeObservation
2LD
2MGOMAG COAT, 8 TO 4 OCLOCK, 25% INTACT
0MWL
2.1MSAVIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON
2MGOGASKET MATERIAL AT THE JOINTS VISIBLE
0AMH09:30 AM
2ISSRH
2.1MGOVIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON
2SAV

Properties (7)

additional_info
VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON
custom_field_two
2
customer
LACSD
datetime
2017-05-24T09:04:06-07:00
documentation
IGNACIO, FRANKLIN, OBREGON
is_lateral_inspection
false
year_laid
19790427