Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2016, 11:29 AM
  • 19 0068_19 0067_20160307_045514.mp4

Date
03/07/2016
W/O
557873
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00724
PipeID
P15100
Time
3:29 AM
Certificate
U507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3217
Sewer Name
19 ELAINE AVENUE TRUNK
City
LAKEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
WO_557873_TV19004_2016MAR
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0068
Downstream MH
19 0067
Dir. of Survey
Downstream
Length Surveyed
296.3 ft.
Total Length
296.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2A00
O&M Rating
22
Overall Index
2
Overall Quick
Overall Rating
25
Pipe schematic from manhole 19 0068 to 19 0067
MH: 19 0068MH: 19 0067downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 00680 ft. MWM - Water Mark, 10 %of cross sectional area4.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.2 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"8.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"10.2 ft. CM - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: NO46.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES51.5 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"54.3 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"103.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"106.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"122.3 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4" - CALCIUM152.8 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"155.9 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"202.7 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"205.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"251 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"254.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"295.2 ft. DNF - Deposits Ingress Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Change296.3 ft. MSA - Survey Abandoned - DUE TO DEBRIS296.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: NO

    10.2 ft. - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: NO

Observations (22)

DistanceCodeObservation
103.2TFC
5.2TBC
296.3MSADUE TO DEBRIS
155.9TBC
54.3TBC
106.4TBC
202.7TBC
205.1TFC
122.3TBACALCIUM
296.3DAGS
254.1TFC
8.4TFC
0MWL
51.5TBC
251TFC
4.2DAGS
295.2DNF
152.8TBC
46.6DAE
10.2CM
0AMH19 0068
0MWM

Properties (6)

additional_info
SC305307
custom_field_two
4
customer
LACSD
datetime
2016-03-07T03:29:02-08:00
documentation
PRO-PIPE
is_lateral_inspection
false