- Date
- 03/10/2016
- W/O
- 557873
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00724
- PipeID
- P15075
- Time
- 3:44 AM
- Certificate
- U507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3221
- Sewer Name
- 19 ELAINE AVENUE TRUNK
- City
- LAKEWOOD, CA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_557873_TV19004_2016MAR
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 19 0045
- Downstream MH
- 19 0044
- Dir. of Survey
- Downstream
- Length Surveyed
- 390.5 ft.
- Total Length
- 390.5 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 412V
- O&M Rating
- 230
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 230
Pipe schematic from manhole 19 0045 to 19 0044 Observation photos (4)

4.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

170 ft. - Infiltration Runner, at 02 o'clock, within 8 inches of joint: YES

205.5 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

261.6 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ MINERAL DEPOSITS