- Date
- 05/23/2017
- W/O
- 0630327
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00799
- PipeID
- P15799
- Time
- 1:23 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0531
- Sewer Name
- 21 TRI-CITIES OUTFALL RELIEF TRUNK
- City
- POMONA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Capital Improvement Program Assesment
- Project
- 20170523MDM_TRI_CITIES_OUTFALL_RELIEF_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 21 0610
- Downstream MH
- 21 0646
- Dir. of Survey
- Downstream
- Length Surveyed
- 7.2 ft.
- Total Length
- 7.2 ft.
- Structural Index
- 5
- Structural Quick
- 5341
- Structural Rating
- 19
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole 21 0610 to 21 0646 Observation photos (5)

0 ft. - General Observation - Conn. @ Mh, 3 O' Clock. Active OUTGOING

2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

5 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM