Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 31, 2015, 09:35 AM
  • 22 0857_22 0856_20151231_014633.mp4

Date
12/31/2015
W/O
531046
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00803
PipeID
P17223
Time
1:35 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2946
Sewer Name
22 DALTON TRUNK, SECTION 3
City
AZUSA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
19
Purpose
Routine Assessment
Project
WO_531046_TV22083_DEC2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
22 0857
Downstream MH
22 0856
Dir. of Survey
Downstream
Length Surveyed
403.4 ft.
Total Length
403.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0857 to 22 0856
MH: 22 0857MH: 22 0856downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 08572 ft. MGO - General Observation - MAGNEZIUM H.O. 60% START127.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"183.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"228.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"284 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"400.7 ft. MGO - General Observation - MAGNEZIUM H.O. 60% FINISH403.4 ft. AMH - Downstream Manhole, Survey Ends - 22 0856

Observation photos (1)

  • General Observation - MAGNEZIUM H.O. 60% START

    2 ft. - General Observation - MAGNEZIUM H.O. 60% START

Observations (10)

DistanceCodeObservation
0MWM
228.7TFC
0MWL
0AMH22 0857
400.7MGOMAGNEZIUM H.O. 60% FINISH
183.3TFC
403.4AMH22 0856
127.1TFC
2MGOMAGNEZIUM H.O. 60% START
284TFC

Properties (6)

additional_info
SC224957
custom_field_two
4
customer
LACSD
datetime
2015-12-31T01:35:06-08:00
documentation
PRO PIPE
is_lateral_inspection
false