Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2015, 10:33 AM
  • 01 0129_01 0128_16122015_013540.mp4

Date
12/16/2015
W/O
524985
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00204
PipeID
P02073
Time
2:33 AM
Certificate
12345
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2963
Sewer Name
01 COMPTON CREEK EXTENSION TRUNK, SECTION 2
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
WO_524985_TV011104_NOV2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
18 in.
Upstream MH
01 0129
Downstream MH
01 0128
Dir. of Survey
Downstream
Length Surveyed
365 ft.
Total Length
365 ft.
Structural Index
2
Structural Quick
332A
Structural Rating
33
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
40
Pipe schematic from manhole 01 0129 to 01 0128
MH: 01 0129MH: 01 0128downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 01297.1 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES53.8 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES96.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES108 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES133.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES148.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES172.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES172.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES194.2 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES202 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES207.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES212.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES212.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES223.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES292.9 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES322.8 ft. CM - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES365 ft. AMH - Downstream Manhole, Survey Ends - 01 0128

Observation photos (16)

  • Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    7.1 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    53.8 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    96.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    108 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    133.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    148.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    172.6 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    172.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    194.2 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    202 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    207.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    212.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    212.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    223.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    292.9 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    322.8 ft. - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
292.9CM
172.6CL
0MWM
194.2CL
148.9CL
53.8CL
0MWL
207.5CL
322.8CM
133.3CM
223.6CL
212.3CL
212.3CL
96.9CL
365AMH01 0128
7.1DAGS
202CL
172.6CL
0AMH01 0129
108CL

Properties (6)

additional_info
SC224802
custom_field_two
3
customer
LACSD
datetime
2015-12-16T02:33:52-08:00
documentation
PRO PIPE
is_lateral_inspection
false