Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 17, 2015, 11:28 AM
  • 01 0162_01 0161_17122015_032959.mp4

Date
12/17/2015
W/O
524985
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00204
PipeID
P02105
Time
3:28 AM
Certificate
12345
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2964
Sewer Name
01 COMPTON CREEK EXTENSION TRUNK, SECTION 2
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
WO_524985_TV011104_NOV2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
15 in.
Upstream MH
01 0162
Downstream MH
01 0161
Dir. of Survey
Downstream
Length Surveyed
356.9 ft.
Total Length
356.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
5241
O&M Rating
22
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 01 0162 to 01 0161
MH: 01 0162MH: 01 0161downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 01620 ft. VC - Vermin Cockroach, within 8 inches of joint: YES0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area7.1 ft. VC - Vermin Cockroach, within 8 inches of joint: YES7.1 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start7.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start354.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish354.9 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish354.9 ft. MGO - General Observation - PIPE MATERIAL LOOKS TO BE CONCRETE356.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0161

Observation photos (2)

  • Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    7.1 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    7.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
354.9DAE
354.9DAGS
0AMH01 0162
7.1VC
0VC
7.1DAGS
7.1DAE
354.9MGOPIPE MATERIAL LOOKS TO BE CONCRETE
0MWL
356.9AMH01 0161
0MWM

Properties (6)

additional_info
SC224803
custom_field_two
4
customer
LACSD
datetime
2015-12-17T03:28:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false