Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2017, 09:55 AM
  • 01 0802_01 1375_12042017_025540.mp4

Date
04/12/2017
W/O
630043
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00197
PipeID
P21617
Time
2:55 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4425
Sewer Name
01 BULLIS ROAD-TEMPLE STREET TRUNK
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
WO_630043_TV01008_APR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1375
Downstream MH
01 0802
Dir. of Survey
Upstream
Length Surveyed
30.3 ft.
Total Length
30.3 ft.
Structural Index
4
Structural Quick
4600
Structural Rating
24
O&M Index
2
O&M Quick
4126
O&M Rating
16
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole 01 1375 to 01 0802
MH: 01 1375MH: 01 0802upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 01 08020 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish28.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start28.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start30.3 ft. MWL - Water Level, 25 %of cross sectional area30.3 ft. MWM - Water Mark, 50 %of cross sectional area30.3 ft. AMH - Downstream Manhole, Survey Begins - 01 1375

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
30.3DAGS
30.3AMH01 0802
0MWL
2DAGS
0MWM
30.3FM
2FM
0AMH01 1375

Properties (6)

additional_info
SC306994
custom_field_two
3
customer
LACSD
datetime
2017-04-12T02:55:12-07:00
documentation
PRO PIPE
is_lateral_inspection
false