Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2017, 07:40 AM
  • 16 0278_16 0277_7102017_021743.mp4

Date
07/10/2017
W/O
0650308
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00654
PipeID
P13326
Time
12:40 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO584R
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 3
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Maintenance Related
Project
20170707MDM_CHAPEL_AVENUE_TRUNK_SECTION_3
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
16 0278
Downstream MH
16 0277
Dir. of Survey
Downstream
Length Surveyed
329 ft.
Total Length
329 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 16 0278 to 16 0277
MH: 16 0278MH: 16 0277downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02:25 AM0 ft. MWL - Water Level, 20 %of cross sectional area87.5 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - LESS THAN 5%329 ft. AMH - Downstream Manhole, Survey Ends - 02:55 AM

Observation photos (1)

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - LESS THAN 5%

    87.5 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - LESS THAN 5%

Observations (5)

DistanceCodeObservation
0MWM
0AMH02:25 AM
329AMH02:55 AM
0MWL
87.5RFJLESS THAN 5%

Properties (4)

customer
LACSD
datetime
2017-07-10T00:40:03-07:00
documentation
REVELES,MANANES,OLIVER III
is_lateral_inspection
false