Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2017, 07:34 AM
  • 16 0280_16 0279_7102017_004658.mp4

  • 16 0280_16 0279_7102017_011757.mp4

Date
07/10/2017
W/O
0650308
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00654
PipeID
P13328
Time
12:34 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO584R
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 3
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Maintenance Related
Project
20170707MDM_CHAPEL_AVENUE_TRUNK_SECTION_3
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
16 0280
Downstream MH
16 0279
Dir. of Survey
Downstream
Length Surveyed
276 ft.
Total Length
276 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 16 0280 to 16 0279
MH: 16 0280MH: 16 0279downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:30 AM0 ft. MWL - Water Level, 40 %of cross sectional area6 ft. MGO - General Observation - CAMERA UNDER WATER DUE TO HIGH FLOW276 ft. AMH - Downstream Manhole, Survey Ends - 02:00 am

Observations (5)

DistanceCodeObservation
6MGOCAMERA UNDER WATER DUE TO HIGH FLOW
0MWM
0AMH12:30 AM
0MWL
276AMH02:00 am

Properties (4)

customer
LACSD
datetime
2017-07-10T00:34:52-07:00
documentation
REVELES,MANANES,OLIVER III
is_lateral_inspection
false