Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2017, 08:47 AM
  • 05 2584_05 2583 _02062017_020550.mp4

Date
06/02/2017
W/O
641198
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z01131
PipeID
P25288
Time
1:47 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4274
Sewer Name
05 COLDEN AVENUE RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_641198_TV05127_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2584
Downstream MH
05 2583
Dir. of Survey
Downstream
Length Surveyed
506.9 ft.
Total Length
506.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 05 2584 to 05 2583
MH: 05 2584MH: 05 2583downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 25840 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start506.9 ft. AMH - Downstream Manhole, Survey Ends - 05 2583506.9 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish506.9 ft. MGO - General Observation - CCTV FOOTAGE DIFFERENT FROM SPREAD SHEET

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2.1DAGS
506.9AMH05 2583
0MWL
0AMH05 2584
0MWM
506.9DAGS
506.9MGOCCTV FOOTAGE DIFFERENT FROM SPREAD SHEET

Properties (7)

additional_info
SC345278
custom_field_two
4
customer
LACSD
datetime
2017-06-02T01:47:01-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
38590