Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2017, 07:55 AM
  • B 1216_B 1215_29062017_005558.mp4

Date
06/29/2017
W/O
640866
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01125
PipeID
P13536
Time
12:55 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4631
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
WO_640866_TV16102_JUN2017
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
B 1216
Downstream MH
B 1215
Dir. of Survey
Downstream
Length Surveyed
233.3 ft.
Total Length
233.3 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
2
O&M Quick
2H00
O&M Rating
88
Overall Index
3
Overall Quick
Overall Rating
226
Pipe schematic from manhole B 1216 to B 1215
MH: B 1216MH: B 1215downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 12160 ft. MWM - Water Mark, 30 %of cross sectional area2.3 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start233.2 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish233.2 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Finish233.3 ft. AMH - Downstream Manhole, Survey Ends - B 1215

Observation photos (2)

  • Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: NO, Start

    13 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start

Observations (8)

DistanceCodeObservation
233.3AMHB 1215
233.2SCP
233.2DSZ
0MWL
0AMHB 1216
2.3SCP
0MWM
13DSZ

Properties (6)

additional_info
SC345348
custom_field_two
3
customer
LACSD
datetime
2017-06-29T00:55:23-07:00
documentation
PROPIPE
is_lateral_inspection
false