Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 6, 2016, 07:10 AM
  • 02 2249_02 2248 _12052016_231505.mp4

Date
12/05/2016
W/O
602592
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00353
PipeID
P04569
Time
11:10 PM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3931
Sewer Name
02 TRACT #5445 RELIEF TRUNK
City
LOS ANGELES, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
WO_602592_TV02117_NOV2016
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 2248
Downstream MH
02 2249
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 02 2248 to 02 2249
MH: 02 2248MH: 02 2249upstream0 ft. MSA - Survey Abandoned - DUE TO SIPHON0 ft. MGO - General Observation - VIEW OF THE UPLEG OF THE DOWSTREAM MH0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES2 ft. AMH - Downstream Manhole, Survey Begins - 02 22482 ft. MWM - Water Mark, 95 %of cross sectional area2 ft. MWL - Water Level, 50 %of cross sectional area

Observation photos (2)

  • General Observation - VIEW OF THE UPLEG OF THE DOWSTREAM MH

    2 ft. - General Observation - VIEW OF THE UPLEG OF THE DOWSTREAM MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
2MSADUE TO SIPHON
0AMH02 2248
0MWM
2MGOVIEW OF THE UPLEG OF THE DOWSTREAM MH
0MWL
2DAGS

Properties (6)

additional_info
SC317675
custom_field_two
4
customer
LACSD
datetime
2016-12-05T23:10:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false