Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 7, 2016, 10:06 AM
  • 02 1145_02 1144_07112016_021141.mp4

Date
11/07/2016
W/O
602268
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00351
PipeID
P02929
Time
2:06 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3817
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Routine Assessment
Project
WO_602268_TV02061_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1145
Downstream MH
02 1144
Dir. of Survey
Downstream
Length Surveyed
227.3 ft.
Total Length
227.3 ft.
Structural Index
3
Structural Quick
3H11
Structural Rating
130
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
130
Pipe schematic from manhole 02 1145 to 02 1144
MH: 02 1145MH: 02 1144downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 11450 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area7.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES15.7 ft. CC - Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES22.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.8 ft. H - Hole, at 01 o'clock, within 8 inches of joint: YES27 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"102.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"202.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"226.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish227.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1144227.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    7.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

    15.7 ft. - Crack Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    22.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole, at 01 o'clock, within 8 inches of joint: YES

    24.8 ft. - Hole, at 01 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
27TB
0AMH02 1145
0MGOCONNECTION AT MH 9 O'CLOCK
154.4TFC
0MWM
227.3AMH02 1144
227.3MGOCONNECTION AT MH 3 O'CLOCK
15.7CC
22.6CM
24.8H
0MGOCONNECTION AT MH 3 O'CLOCK
202.4TFC
7.2CM
226.2CM
0MWL
102.7TFC

Properties (6)

additional_info
SC304566
custom_field_two
2
customer
LACSD
datetime
2016-11-07T02:06:30-08:00
documentation
PRO-PIPE
is_lateral_inspection
false