Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2017, 07:27 AM
  • 08 0151_08 0150_622017_003533.mp4

Date
06/02/2017
W/O
0635421
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00006
PipeID
P00207
Time
12:27 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0547
Sewer Name
08 FIGUEROA STREET TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
20170602MDM_FIGUEROA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
11.100000381469727 in.
Upstream MH
08 0151
Downstream MH
08 0150
Dir. of Survey
Downstream
Length Surveyed
300.8 ft.
Total Length
300.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 08 0151 to 08 0150
MH: 08 0151MH: 08 0150downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:30AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area8 ft. MGP - General Photograph - 11.1" VCP+PEP LINER195.8 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open297 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open300.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active300.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active300.8 ft. AMH - Downstream Manhole, Survey Ends - 1:00AM

Observation photos (1)

  • General Photograph - 11.1" VCP+PEP LINER

    8 ft. - General Photograph - 11.1" VCP+PEP LINER

Observations (9)

DistanceCodeObservation
297TBOpen
0AMH12:30AM
0MWM
8MGP11.1" VCP+PEP LINER
300.5MGOConn. @ Mh, 9 O' Clock. Active
195.8TBOpen
300.5MGOConn. @ Mh, 3 O' Clock. Active
300.8AMH1:00AM
0MWL

Properties (8)

custom_field_three
LINER GOOG COND.
custom_field_two
4
customer
LACSD
datetime
2017-06-02T00:27:02-07:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false
lining
PEP-Deformed/Reforme
year_laid
20020802