21 0933_21 0932_452017_124155.mp4
2 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
15.5 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES
38.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
48 ft. - General Photograph - INTRUDING CONNECTION @ 9 O'CLOCK
58.9 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
66.3 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES
71.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES
88.8 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES
101.6 ft. - Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES
126.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
128.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
144 ft. - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES
181.6 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES
191.5 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES
212.6 ft. - Tap Break-In Defective, at 09 o'clock, -, , within 8 inches of joint: YES, 4" - Open
246.4 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES
318.3 ft. - General Photograph - INTRUDING CONNECTION @ 9 O'CLOCK/1"
375.6 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 4" - Active
375.6 ft. - General Observation - INTRUDING CONNECTION @ 12 O'CLOCK/1"
389 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES
420.2 ft. - General Photograph - INTRUDING CONNECTION @ 12 O'CLOCK/1"
433.7 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES
487.6 ft. - Tap Break-In Defective, at 09 o'clock, -, , within 8 inches of joint: YES, 4" - Open
600.2 ft. - Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES
600.2 ft. - Broken, from 08 to 12 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 66.3 | CM | — |
| 2 | CM | — |
| 318.3 | TBA | — |
| 6 | CL | — |
| 0 | MWL | — |
| 101.6 | FS | — |
| 0 | AMH | 11:50 AM |
| 128.6 | DAGS | — |
| 335 | TFC | — |
| 318.3 | MGP | INTRUDING CONNECTION @ 9 O'CLOCK/1" |
| 0 | MWM | — |
| 181.6 | CL | — |
| 420.2 | TB | Open |
| 568.8 | TFC | — |
| 58.9 | FL | — |
| 600.2 | FM | — |
| 48 | MGP | INTRUDING CONNECTION @ 9 O'CLOCK |
| 88.8 | CM | — |
| 0 | MGO | Conn. @ Mh, 4 O' Clock. UNKNOWN |
| 690.1 | CM | — |
| 191.5 | FL | — |
| 433.7 | FL | — |
| 487.6 | TBD | Open |
| 198.4 | TB | Open/40% GREASE |
| 126.4 | CM | — |
| 690.4 | AMH | 1:51 PM |
| 389 | FM | — |
| 420.2 | MGP | INTRUDING CONNECTION @ 12 O'CLOCK/1" |
| 375.6 | TBD | Active |
| 375.6 | MGO | INTRUDING CONNECTION @ 12 O'CLOCK/1" |
| 15.5 | CL | — |
| 38.7 | FM | — |
| 246.4 | FL | — |
| 48.3 | TB | Open |
| 600.2 | B | — |
| 144 | FS | — |
| 71.3 | FL | — |
| 212.6 | TBD | Open |
| 180.2 | TB | Open |
| 690.1 | SSS | — |
| 571.8 | TB | Open |
| 2 | SSS | — |