Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2017, 08:23 AM
  • 15 0363_15 0362_3312017_020535.mp4

Date
03/31/2017
W/O
0619136
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00598
PipeID
P12289
Time
1:23 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0480
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
20170331MDM_BALDWIN_PARK_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
15 0363
Downstream MH
15 0362
Dir. of Survey
Downstream
Length Surveyed
235.8 ft.
Total Length
235.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
4
O&M Quick
4200
O&M Rating
8
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole 15 0363 to 15 0362
MH: 15 0363MH: 15 0362downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 90% 9:00 TO 3:00 START49.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped52.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG61.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open94.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open102 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open138.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped143 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped195.5 ft. MWM - Water Mark, 60 %of cross sectional area204.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped235.4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG235.4 ft. MGO - General Observation - MAG COAT 90%235.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active235.8 ft. AMH - Downstream Manhole, Survey Ends - 2:05AM

Observation photos (3)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 90% 9:00 TO 3:00 START

    2 ft. - General Observation - MAG COAT 90% 9:00 TO 3:00 START

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    52.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

Observations (19)

DistanceCodeObservation
235.4SAVSEVERE AGG
195.5MWM
49.6TFCCapped
94.4TFOpen
0MWL
61.4TFOpen
0MWM
143TFCCapped
204.2TFCCapped
235.4MGOMAG COAT 90%
102TFOpen
0MGOConn. @ Mh, 3 O' Clock. Active
2SAVSEVERE AGG
2MGOMAG COAT 90% 9:00 TO 3:00 START
138.7TFCCapped
0AMH1:45AM
235.8AMH2:05AM
235.4MGOConn. @ Mh, 9 O' Clock. Active
52.8SAVSEVERE AGG

Properties (6)

custom_field_three
SEVERE AGG VISIBLE
custom_field_two
4
customer
LACSD
datetime
2017-03-31T01:23:57-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false