- Date
- 05/16/2017
- W/O
- 618894
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00258
- PipeID
- P03199
- Time
- 11:46 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4455
- Sewer Name
- 02 EAST COMPTON BOULEVARD EXTENSION TRUNK
- City
- DOWNEY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- WO_618894_TV02057_MAY2017
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 02 0645
- Downstream MH
- 02 0692
- Dir. of Survey
- Upstream
- Length Surveyed
- 179.8 ft.
- Total Length
- 179.8 ft.
- Structural Index
- 3
- Structural Quick
- 3300
- Structural Rating
- 9
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 02 0645 to 02 0692 Observation photos (3)

50.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

99.4 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

107.2 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES