Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 6, 2016, 09:34 AM
  • 01 0170A_01 0170_06092016_023542.mp4

Date
09/06/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01198
Time
2:34 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3579
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0170A
Downstream MH
01 0170
Dir. of Survey
Downstream
Length Surveyed
49.7 ft.
Total Length
49.7 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0170A to 01 0170
MH: 01 0170AMH: 01 0170downstream0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 0170A0 ft. MWL - Water Level, 5 %of cross sectional area6.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"17.3 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES42.9 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES49.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0170

Observation photos (2)

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    17.3 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    42.9 ft. - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
17.3CM
49.7AMH01 0170
42.9CM
0MGOLATERAL AT MH 3 OCLOCK
0MWM
0AMH01 0170A
6.2TFC
0MWL

Properties (6)

additional_info
SC306169
custom_field_two
4
customer
LACSD
datetime
2016-09-06T02:34:49-07:00
documentation
PROPIPE
is_lateral_inspection
false