Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2016, 09:02 AM
  • 01 0176B_01 0176A_31082016_020300.mpg

Date
08/31/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01211
Time
2:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3576
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0176A
Downstream MH
01 0176B
Dir. of Survey
Upstream
Length Surveyed
324.1 ft.
Total Length
324.1 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 01 0176A to 01 0176B
MH: 01 0176AMH: 01 0176Bupstream0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 01 0176B0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK25.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES35.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"43.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"61.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"78.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"107.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"131.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"133.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"139.9 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"157.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"181.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"207.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"233.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"256.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"259.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"283.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"286.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"287.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES309.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"312.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"321.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES324.1 ft. MWM - Water Mark, 20 %of cross sectional area324.1 ft. MWL - Water Level, 15 %of cross sectional area324.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK324.1 ft. AMH - Downstream Manhole, Survey Begins - 01 0176A

Observation photos (4)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    2.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    36.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"

    184.2 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    298.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (33)

DistanceCodeObservation
11.4TFC
190.2TF
324.1MGOLATERAL AT MH 3 OCLOCK
289TFC
67.4TF
38TF
298.3CM
14.5TFC
219.2TF
263TFC
0MWM
102.3TF
324.1AMH01 0176B
116.9TF
139.9TFC
324.1MGOLATERAL AT MH 9 OCLOCK
2.9FL
192.3TFC
0MWL
119.2TF
245.6TF
90.5TF
36.9DAGS
142.4TFC
166.3TFC
239.5TFC
64.4TFC
281TFC
0MGOLATERAL AT MH 9 OCLOCK
216.5TFC
0AMH01 0176A
40.8TFC
184.2TB

Properties (6)

additional_info
SC306166
custom_field_two
4
customer
LACSD
datetime
2016-08-31T02:02:21-07:00
documentation
PROPIPE
is_lateral_inspection
false