Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2016, 10:42 AM
  • 01 0194_01 0193_083016_035540.mpg

Date
08/30/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01236
Time
3:42 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3575
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0194
Downstream MH
01 0193
Dir. of Survey
Downstream
Length Surveyed
270.8 ft.
Total Length
270.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 0194 to 01 0193
MH: 01 0194MH: 01 0193downstream0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 01940 ft. MWM - Water Mark, 20 %of cross sectional area4.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"17.1 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"41.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"59.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"80.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.8 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"100.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"103.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"112.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"135.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"135.2 ft. RFC - Roots Fine Connection, at 10 o'clock154.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.5 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES211.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"249.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"258.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"266 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish270.7 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK270.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0193

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"

    17.1 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"

    86.8 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    112.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    135.2 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Roots Fine Connection, at 10 o'clock

    135.2 ft. - Roots Fine Connection, at 10 o'clock

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

    175.5 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

Observations (26)

DistanceCodeObservation
135.2TB
219.7TF
0MGOLATERAL AT MH 3 OCLOCK
258.3TF
211.2TFC
154.6TFC
159.9TF
41.5TFC
103.7TF
266CM
59.3TF
0MWL
100.9TF
80.2TFC
12TFC
175.5RFJ
4.2CM
86.8TB
270.7MGOLATERAL AT MH 9 OCLOCK
135.2RFC
17.1TB
0AMH01 0194
270.8AMH01 0193
0MWM
249.8TF
112.2TB

Properties (6)

additional_info
SC306165
custom_field_two
3
customer
LACSD
datetime
2016-08-30T03:42:34-07:00
documentation
PROPIPE
is_lateral_inspection
false