Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 7, 2016, 05:36 AM
  • 01 1008_01 1007_06092016_223708.mp4

Date
09/06/2016
W/O
585982
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00221
PipeID
P01854
Time
10:36 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3580
Sewer Name
01 VERNON EXTENSION TRUNK
City
VERNON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
WO_585982_TV01065_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
01 1008
Downstream MH
01 1007
Dir. of Survey
Downstream
Length Surveyed
311.7 ft.
Total Length
311.7 ft.
Structural Index
2
Structural Quick
2C00
Structural Rating
38
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
38
Pipe schematic from manhole 01 1008 to 01 1007
MH: 01 1008MH: 01 1007downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 10080 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area10.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES14.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"16.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES22.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start28.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"51.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish87.3 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"128.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"195.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES201 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"209 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"231.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"252 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start301.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish310.6 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK311.7 ft. AMH - Downstream Manhole, Survey Ends - 01 1007

Observation photos (9)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    10.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    14.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    16.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    22.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

    87.3 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    195.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    201 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    209 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    252 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
227.9TFC
14.1TB
231.5TF
22.9CL
195.8CL
301.4CL
310.6MGOLATERAL AT MH 9 OCLOCK
87.3TB
28.1TFC
51.6CL
209TB
311.7AMH01 1007
10.5CL
0AMH01 1008
128.1TFC
16.6CL
201TB
252CL
0MWL
0MWM

Properties (6)

additional_info
SC306170
custom_field_two
3
customer
LACSD
datetime
2016-09-06T22:36:12-07:00
documentation
PROPIPE
is_lateral_inspection
false