- Date
- 09/13/2016
- W/O
- 585982
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00221
- PipeID
- P01827
- Time
- 2:19 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3581
- Sewer Name
- 01 VERNON EXTENSION TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_585982_TV01065_AUG2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 01 0987
- Downstream MH
- 01 1097
- Dir. of Survey
- Downstream
- Length Surveyed
- 406.5 ft.
- Total Length
- 406.5 ft.
- Structural Index
- 2
- Structural Quick
- 2111
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 01 0987 to 01 1097 Observation photos (3)

60.9 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

73 ft. - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES

191.3 ft. - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"