Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2016, 06:24 AM
  • 01 0995_01 0994_12092016_232408.mp4

Date
09/12/2016
W/O
585982
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00221
PipeID
P01835
Time
11:24 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3581
Sewer Name
01 VERNON EXTENSION TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
WO_585982_TV01065_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
01 0995
Downstream MH
01 0994
Dir. of Survey
Downstream
Length Surveyed
337.7 ft.
Total Length
337.7 ft.
Structural Index
2
Structural Quick
2212
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0995 to 01 0994
MH: 01 0995MH: 01 0994downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 09950 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area25.6 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES146.8 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES149.5 ft. CC - Crack Circumferential, from 04 to 05 o'clock, within 8 inches of joint: YES189.8 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES337.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0994

Observation photos (4)

  • Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES

    25.6 ft. - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    146.8 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 04 to 05 o'clock, within 8 inches of joint: YES

    149.5 ft. - Crack Circumferential, from 04 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    189.8 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0AMH01 0995
0MWL
337.7AMH01 0994
0MWM
189.8CL
146.8CL
149.5CC
25.6CC

Properties (6)

additional_info
SC306174
custom_field_two
4
customer
LACSD
datetime
2016-09-12T23:24:00-07:00
documentation
PROPIPE
is_lateral_inspection
false