Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 30, 2017, 07:32 AM
  • 01 1226_01 1225_5302017_003709.mp4

Date
05/30/2017
W/O
0635395
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00217
PipeID
P02050
Time
12:32 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0539
Sewer Name
01 SANTA FE AVENUE TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
20170526MDM_SANTA_FE_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 1225
Downstream MH
01 1226
Dir. of Survey
Upstream
Length Surveyed
146.9 ft.
Total Length
146.9 ft.
Structural Index
2
Structural Quick
352C
Structural Rating
55
O&M Index
3
O&M Quick
3400
O&M Rating
12
Overall Index
2
Overall Quick
Overall Rating
67
Pipe schematic from manhole 01 1225 to 01 1226
MH: 01 1225MH: 01 1226upstream0 ft. AMH - Upstream Manhole, Survey Ends :COMPLETED BY REVERESE INSPECTION - 1:05AM:COMPLETED BY REVERSE INSPECTION0.6 ft. RMJ - Roots Medium Joint, from 07 to 10 o'clock, 25 %, within 8 inches of joint: YESR0.6 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR, Finish1.9 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL4.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - H7.2 ft. FC - Fracture Circumferential, from 08 to 03 o'clock, within 8 inches of joint: YES - H12.5 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR, Start12.5 ft. FC - Fracture Circumferential, from 11 to 03 o'clock, within 8 inches of joint: YES - H14.8 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR14.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H20.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H20.4 ft. RMJ - Roots Medium Joint, from 03 to 05 o'clock, 5 %, within 8 inches of joint: YESR24.9 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL24.9 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H35.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL37.7 ft. MWM - Water Mark, 30 %of cross sectional area37.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H49.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open62.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open73.6 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL78.8 ft. MGO - General Observation - 15" VCP78.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H78.8 ft. MWM - Water Mark, 40 %of cross sectional area91.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H96.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H96.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H104.4 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H112.1 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H114.5 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - SL119.6 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H127.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL129.9 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H134.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL134.9 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SL137.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT142.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES, - HAIRLINE146.9 ft. MWL - Water Level, 10 %of cross sectional area146.9 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active146.9 ft. AMH - Downstream Manhole, Survey Begins - 12:35AM146.9 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (2)

  • General Observation - 15" VCP

    68.1 ft. - General Observation - 15" VCP

  • Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR, Start

    134.4 ft. - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR, Start

Observations (40)

DistanceCodeObservation
42.5FCH
9.4FCSLIGHT
122FCSL
12FLSL
0MWL
146.3RMJ
50.1FLH
0MGOConn. @ Mh, 3 O' Clock. Active
68.1MGO15" VCP
34.8FCH
145FCSL
132.1RMJ
146.9AMH1:05AM:COMPLETED BY REVERSE INSPECTION
68.1FLH
0AMH12:35AM
146.3RMJ
17FCH
32.4FCSL
122FCH
134.4RMJ
134.4FCH
97.5TFOpen
139.7FCH
0MWM
126.5FCH
73.3FCSL
4FCHAIRLINE
27.3FCH
55.2FLH
142.4FCH
109.2MWM
12FCSL
126.5RMJ
84.4TFOpen
111.6FCSL
68.1MWM
50.1FCH
109.2FLH
19.6FCSL
132.1FCH

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2017-05-30T00:32:45-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false