Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2017, 08:49 AM
  • 15 0773_15 0772_592017_015823.mp4

Date
05/09/2017
W/O
0619123
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12974
Time
1:49 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0519
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20170509MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0773
Downstream MH
15 0772
Dir. of Survey
Downstream
Length Surveyed
134.9 ft.
Total Length
134.9 ft.
Structural Index
3
Structural Quick
4122
Structural Rating
8
O&M Index
3
O&M Quick
4232
O&M Rating
19
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole 15 0773 to 15 0772
MH: 15 0773MH: 15 0772downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG16 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open-30% ROOTS21.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AG ATTCHED50.5 ft. RMJ - Roots Medium Joint, from 08 to 12 o'clock, 5 %, within 8 inches of joint: YESR82 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped93.2 ft. RMJ - Roots Medium Joint, from 01 to 04 o'clock, 5 %, within 8 inches of joint: YESR108.1 ft. RFJ - Roots Fine Joint, from 01 to 03 o'clock, within 8 inches of joint: YESR - 3%131.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped133.3 ft. RBL - Roots Ball Lateral, from 08 to 04 o'clock, 70 %, within 8 inches of joint: YES133.3 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active 95% ROOTS134.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE SEVERE AGG ATTCHED134.4 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG134.9 ft. MSA - Survey Abandoned - 70% ROOTS

Observation photos (5)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AG ATTCHED

    21.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AG ATTCHED

  • Roots Ball Lateral, from 08 to 04 o'clock, 70 %, within 8 inches of joint: YES

    133.3 ft. - Roots Ball Lateral, from 08 to 04 o'clock, 70 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active 95% ROOTS

    133.3 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active 95% ROOTS

Observations (18)

DistanceCodeObservation
134.4SSSPEELING CONCRETE SEVERE AGG ATTCHED
133.3RBL
2SSSPEELING CONCRETE SEVERE AGG ATTACHED
21.2SSSPEELING CONCRETE SEVERE AG ATTCHED
93.2RMJ
0MGOConn. @ Mh, 3 O' Clock. Active
134.9MSA70% ROOTS
133.3TFDActive 95% ROOTS
50.5RMJ
2SAMSEVERE AGG
131.2TFCCapped
134.4SAMSEVERE AGG
0MWM
16TFDOpen-30% ROOTS
0AMH1:55AM
0MWL
108.1RFJ3%
82TFCCapped

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTCHED
custom_field_two
2
customer
LACSD
datetime
2017-05-09T01:49:10-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false