Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2017, 07:29 AM
  • 02 0309_02 0308_6282017_011730.mp4

Date
06/28/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02623
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0576
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
19A
Purpose
Routine Assessment
Project
20170626MDM_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0308
Downstream MH
02 0309
Dir. of Survey
Upstream
Length Surveyed
334.9 ft.
Total Length
334.9 ft.
Structural Index
2
Structural Quick
362C
Structural Rating
58
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
58
Pipe schematic from manhole 02 0308 to 02 0309
MH: 02 0308MH: 02 0309upstream0 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM0.5 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - 30% HAIRLINE AT JOINTS0.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - 15% SLIGHT AT JOINTS0.5 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - 20% SLIGHT AT JOINTS0.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - 20% HAIRLINE AT JOINTS4.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active31 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped130.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open227.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open254.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS254.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS254.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS254.3 ft. MGO - General Observation - WHITE BUILD UP ON PIPE254.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - HAIRLINES AT JOINTS258.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H258.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H262.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H266.6 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H266.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL274.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL275.1 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - H278.1 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H282.5 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H290.8 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL295.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open302 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H306.2 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H310.2 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL310.2 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - SL314 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H318.2 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL318.2 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - H322.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE322.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL326.5 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL328.9 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SLIGHT328.9 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT334.9 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM334.9 ft. MWL - Water Level, 30 %of cross sectional area334.9 ft. MWM - Water Mark, 40 %of cross sectional area334.9 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active

Observation photos (1)

  • General Observation - WHITE BUILD UP ON PIPE

    80.6 ft. - General Observation - WHITE BUILD UP ON PIPE

Observations (41)

DistanceCodeObservation
0AMH12:45AM
334.4FC30% HAIRLINE AT JOINTS
72.5FLH
76.6FCH
80.6FLHAIRLINE AT JOINTS
204.2TFOpen
6FCSLIGHT
12.6FLHAIRLINE
107.5TFOpen
68.3FCH
20.9FCH
52.4FCH
16.7FCSL
334.4FL15% SLIGHT AT JOINTS
16.7FCH
59.8FCH
44.1FCSL
76.6FCH
60.6FLSL
8.4FCSL
0MWL
39.4TFOpen
80.6FLSLIGHT AT JOINTS
303.9TFCCapped
334.4FC20% SLIGHT AT JOINTS
334.9AMH1:35AM
330.6TBActive
334.4FL20% HAIRLINE AT JOINTS
80.6FCSLIGHT AT JOINTS
56.8FCH
32.9FLH
28.7FCH
12.5FCSL
24.7FCSL
24.7FCSL
68.3FCSL
0MWM
6FCSLIGHT
80.6MGOWHITE BUILD UP ON PIPE
80.6FCHAIRLINES AT JOINTS
0MGOConn. @ Mh, 9 O' Clock. Active

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2017-06-28T00:29:02-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false