Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 5, 2017, 08:31 AM
  • 01 0650_01 0649_152017_040323.mp4

Date
01/05/2017
W/O
0607746
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00212
PipeID
P01149
Time
12:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0383
Sewer Name
01 MOUNTAIN VIEW-BELLE VERNON TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20170103MDM_MOUNTAIN_VIEW_BELLE_VERNON_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 0650
Downstream MH
01 0649
Dir. of Survey
Downstream
Length Surveyed
374.8 ft.
Total Length
374.8 ft.
Structural Index
2
Structural Quick
352B
Structural Rating
45
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
45
Pipe schematic from manhole 01 0650 to 01 0649
MH: 01 0650MH: 01 0649downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:55AM0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 5 %of cross sectional area18 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE20.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H26.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT28.5 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H31.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H33.5 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL36.4 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES - H39.1 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H49.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL49.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H51.7 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL60.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open69.7 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL74.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H75.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE85.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H90.1 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL93.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS93.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS93.3 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS93.3 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS96.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active135.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open165.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped177 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open179 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open194.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped207.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open217.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active271.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open276.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open309 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open312.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active357.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE365.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active367.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H374.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40%HAIRLINE AT JOINTS374.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 30% SLIGHT AT JOINTS374.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 60%SLIGHT AT JOINTS374.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active374.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 30% HAIRLINE AT JOINTS374.8 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM

Observation photos (1)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    357.7 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

Observations (46)

DistanceCodeObservation
374.5FC40%HAIRLINE AT JOINTS
177TBOpen
93.3FCHAIRLINE AT JOINTS
357.7FLHAIRLINE
271.3TFOpen
165.9TFCCapped
207.4TFOpen
75.9TFACTIVE
85.2FLH
39.1FCH
93.3FCSLIGHT AT JOINTS
90.1FCSL
93.3FLSLIGHT AT JOINTS
374.5FL30% SLIGHT AT JOINTS
194.5TFCCapped
367.7FLH
374.8AMH4:55AM
51.7FCSL
276.7TFOpen
60.5TFOpen
217.7TFActive
312.5TFActive
49.3FCSL
33.5FCSL
0AMH3:55AM
0MWM
49.3FCH
28.5FCH
36.4FCH
374.5FC60%SLIGHT AT JOINTS
96.3TFActive
31.4FCH
69.7FCSL
374.5MGOConn. @ Mh, 3 O' Clock. Active
93.3FLHAIRLINE AT JOINTS
74.9FLH
365.9TBActive
18FCHAIRLINE
374.5FL30% HAIRLINE AT JOINTS
0MGOConn. @ Mh, 3 O' Clock. Active
309TFOpen
179TFOpen
20.8FCH
26.2FCSLIGHT
0MWL
135.8TFOpen

Properties (6)

custom_field_three
HAIRLINE LONG FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2017-01-05T00:31:18-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false