Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 24, 2017, 09:20 AM
  • 21 0434A_21 0434_3242017_022602.mp4

Date
03/24/2017
W/O
0624443
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00788
PipeID
P15642
Time
2:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0476
Sewer Name
21 5TH AVENUE TRUNK
City
DIAMOND BAR
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
36
Purpose
Routine Assessment
Project
20170324MDM_5TH_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
21 0434A
Downstream MH
21 0434
Dir. of Survey
Downstream
Length Surveyed
227.8 ft.
Total Length
227.8 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 21 0434A to 21 0434
MH: 21 0434AMH: 21 0434downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:20AM87.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped139.5 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE196 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped220.3 ft. MGO - General Observation - 18" VCP227.8 ft. AMH - Downstream Manhole, Survey Ends - 2:35AM

Observation photos (1)

  • General Observation - 18" VCP

    220.3 ft. - General Observation - 18" VCP

Observations (9)

DistanceCodeObservation
196TFCCapped
139.5FCHAIRLINE
0MWM
87.5TFCCapped
0MGOConn. @ Mh, 9 O' Clock. Active
0MWL
227.8AMH2:35AM
0AMH2:20AM
220.3MGO18" VCP

Properties (6)

custom_field_three
1 HAIRLINE CIRCUM
custom_field_two
4
customer
LACSD
datetime
2017-03-24T02:20:00-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false