Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2018, 11:51 AM
  • 05 1482_05 1481A_472018_045633.mp4

Date
04/07/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00438
PipeID
P06707
Time
4:51 AM
Certificate
U-1014-0602253
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Heavy Cleaning
Media Label
H0809
Sewer Name
05 EL NIDO TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
23
Purpose
Maintenance Related
Project
20180407MDM_EL_NIDO_TRUNK
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
05 1482
Downstream MH
05 1481A
Dir. of Survey
Downstream
Length Surveyed
210.7 ft.
Total Length
210.7 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 1482 to 05 1481A
MH: 05 1482MH: 05 1481Adownstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. STUB0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:55AM0 ft. MWL - Water Level, 0 %of cross sectional area - DRY LINE2 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED28.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped88.1 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED99 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 5" - Capped180.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped210 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active210 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE SEVERE AGG ATTACHED210.7 ft. AMH - Downstream Manhole, Survey Ends - 5:10AM

Observation photos (2)

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start -  PEELING CONCRETE SEVERE AGG ATTACHED

    2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped

    28.9 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped

Observations (12)

DistanceCodeObservation
180.8TFCCapped
210MGOConn. @ Mh, 9 O' Clock. Active
0MGOConn. @ Mh, 3 O' Clock. STUB
2SSSPEELING CONCRETE SEVERE AGG ATTACHED
88.1SSSPEELING CONCRETE SEVERE AGG ATTACHED
0MWM
28.9TFCCapped
99TFCCapped
0AMH4:55AM
210SSSPEELING CONCRETE SEVERE AGG ATTACHED
210.7AMH5:10AM
0MWLDRY LINE

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
2
customer
LACSD
datetime
2018-04-07T04:51:22-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false