- Date
- 04/05/2018
- W/O
- 0696832
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00323
- PipeID
- P08086
- Time
- 1:28 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7676
- Sewer Name
- A JOA-1A LOS COYOTES WRP INTERCEPTOR
- City
- BELLFLOWER
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 37
- Purpose
- Routine Assessment
- Project
- 20180405SHO_JOA1A_LC_WRP_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 66 in.
- Upstream MH
- A 0149
- Downstream MH
- A 0148
- Dir. of Survey
- Downstream
- Length Surveyed
- 470.3 ft.
- Total Length
- 470.3 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole A 0149 to A 0148 Observation photos (2)

10 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

17.9 ft. - General Observation - AIR VENT